Bimetallic temperature sensitive switch with manual reset - Thermorex TK34MR

This thermostat comes in 3 variations: automatic operation, manual reset and with resistance based internal heater. This thermostat can be used in high current applications (up to 45A).

This thermostat can be built to either open or close its electrical contacts as the temperature increases. Once the temperature of the bimetal disc has returned to the specified reset temperature, the contacts will automatically return to their original state.

Besides its variety of standard configurations the thermostat can also be customized to the specific technical needs of the customer, assuring maximum design flexibility and usage in broad range of temperature control applications for consumer, industrial and commercial products.

 Prospekt herunterladen
BASIC TECHNICAL DATA
Parameter Value
Nominal voltage, V, not more ~250
Nominal current, A, at power coeff. 0.95, not more 16; 10
Number of automatic cycles, at nominal current 16 А and power coeff. 0.95, not less than 30000
Number of automatic cycles, at nominal current 10 А and power coeff. 0.95, not less than 100000
Schalttemperatur in °C 50°C — 120°C
Toleranzbereich der Schalttemperatur in °C ±3
Rückschaltttemperatur, niedriger als Betriebstemperatur, in °C 20 (for response temperature 30-130°C);
35 (for response temperature 131-190°C)
max. Durchgangswiderstand in &Omega 0.05
Spannungsfestigkeit in V, mindestens 1500
Isolationswiderstand in MΩ, mindestens 50
Erhöhung der Temperatur in K/min minimum-0.1; maximum-1.0
Isolationswert IP4X